parent
1c719a214d
commit
a33d7582fb
|
|
@ -66,19 +66,19 @@ fi
|
|||
|
||||
# 6. 检查IB网卡排列顺序
|
||||
value3=$(cat << EOF
|
||||
hca_id: mlx5_0
|
||||
hca_id: mlx5_1
|
||||
hca_id: mlx5_2
|
||||
hca_id: mlx5_3
|
||||
hca_id: mlx5_4
|
||||
hca_id: mlx5_5
|
||||
hca_id: mlx5_6
|
||||
hca_id: mlx5_7
|
||||
hca_id: mlx5_bond_0
|
||||
hca_id: mlx5_bond_1
|
||||
mlx5_bond_0 port 1 ==> bond0 (Up)
|
||||
mlx5_bond_1 port 1 ==> bond1 (Up)
|
||||
mlx5_bond_2 port 1 ==> bond2 (Up)
|
||||
mlx5_bond_3 port 1 ==> bond3 (Up)
|
||||
mlx5_bond_4 port 1 ==> bond4 (Up)
|
||||
mlx5_bond_5 port 1 ==> bond5 (Up)
|
||||
mlx5_bond_6 port 1 ==> bond6 (Up)
|
||||
mlx5_bond_7 port 1 ==> bond7 (Up)
|
||||
mlx5_bond_8 port 1 ==> bond8 (Up)
|
||||
mlx5_bond_9 port 1 ==> bond9 (Up)
|
||||
EOF
|
||||
)
|
||||
value4=$(ibv_devinfo | grep mlx)
|
||||
value4=$(ibdev2netdev)
|
||||
if ! test "$value3" = "$value4"; then
|
||||
echo "node_cluster_check_ib_order 1" >> $TMP_FILE
|
||||
else
|
||||
|
|
@ -87,12 +87,16 @@ fi
|
|||
|
||||
# 7. 检查硬盘数量
|
||||
disk_error=0
|
||||
if ! lsblk | grep nvme5n1 > /dev/null; then
|
||||
disk_error=1
|
||||
elif lsblk | grep nvme6n1 > /dev/null; then
|
||||
TARGET_DISKS=("nvme0n1" "nvme1n1" "nvme2n1" "nvme3n1")
|
||||
for disk in "${TARGET_DISKS[@]}"; do
|
||||
if ! lsblk | grep -w "$disk" > /dev/null; then
|
||||
disk_error=1
|
||||
break
|
||||
fi
|
||||
echo "node_cluster_check_disk_count $disk_error" >> $TMP_FILE
|
||||
done
|
||||
|
||||
echo "node_cluster_check_disk_count $disk_error" >> "$TMP_FILE"
|
||||
|
||||
|
||||
# 8. 检查内存品牌一致性
|
||||
memory2=$(sudo dmidecode -t memory | grep -i "Manufacturer:" | uniq | wc -l)
|
||||
|
|
@ -119,24 +123,24 @@ else
|
|||
fi
|
||||
|
||||
# 11. 检查风扇模式
|
||||
fan_mode=$(racadm get system.thermalsettings.ThermalProfile 2>/dev/null | grep -c 'ThermalProfile=Maximum Performance')
|
||||
if [ "$fan_mode" -ne 1 ]; then
|
||||
echo "node_cluster_check_fan_mode 1" >> $TMP_FILE
|
||||
else
|
||||
echo "node_cluster_check_fan_mode 0" >> $TMP_FILE
|
||||
fi
|
||||
#fan_mode=$(racadm get system.thermalsettings.ThermalProfile 2>/dev/null | grep -c 'ThermalProfile=Maximum Performance')
|
||||
#if [ "$fan_mode" -ne 1 ]; then
|
||||
# echo "node_cluster_check_fan_mode 1" >> $TMP_FILE
|
||||
#else
|
||||
# echo "node_cluster_check_fan_mode 0" >> $TMP_FILE
|
||||
#fi
|
||||
|
||||
# 12. 检查风扇转速
|
||||
fan_speed=$(racadm get system.thermalsettings.FanSpeedOffset 2>/dev/null | grep -c 'FanSpeedOffset=Max')
|
||||
if [ "$fan_speed" -ne 1 ]; then
|
||||
echo "node_cluster_check_fan_speed 1" >> $TMP_FILE
|
||||
else
|
||||
echo "node_cluster_check_fan_speed 0" >> $TMP_FILE
|
||||
fi
|
||||
#fan_speed=$(racadm get system.thermalsettings.FanSpeedOffset 2>/dev/null | grep -c 'FanSpeedOffset=Max')
|
||||
#if [ "$fan_speed" -ne 1 ]; then
|
||||
# echo "node_cluster_check_fan_speed 1" >> $TMP_FILE
|
||||
#else
|
||||
# echo "node_cluster_check_fan_speed 0" >> $TMP_FILE
|
||||
#fi
|
||||
|
||||
# 13. 检查IB链路BER值
|
||||
for i in {0..7}; do
|
||||
dev="mlx5_$i"
|
||||
for i in {2..9}; do
|
||||
dev="mlx5_bond_$i"
|
||||
ber_value=$(mlxlink -d $dev -c 2>/dev/null | grep 'Symbol BER' | awk -F- '{print $2}' | xargs)
|
||||
if [[ -n "$ber_value" && "$ber_value" -lt 14 ]]; then
|
||||
echo "node_cluster_check_ib_ber{device=\"$dev\"} 1" >> $TMP_FILE
|
||||
|
|
@ -146,8 +150,8 @@ for i in {0..7}; do
|
|||
done
|
||||
|
||||
# 14. 检查IB网卡光衰
|
||||
for i in {0..7}; do
|
||||
dev="mlx5_$i"
|
||||
for i in {2..9}; do
|
||||
dev="mlx5_bond_$i"
|
||||
output=$(mlxlink -d "$dev" -m 2>/dev/null | grep -E 'Tx Power Current|Rx Power Current')
|
||||
power_error=0
|
||||
|
||||
|
|
@ -171,14 +175,14 @@ for i in {0..7}; do
|
|||
done
|
||||
|
||||
# 15. 检查IB网卡带宽
|
||||
for i in {0..7}; do
|
||||
dev="mlx5_$i"
|
||||
for i in {2..9}; do
|
||||
dev="mlx5_bond_$i"
|
||||
bandwidth_error=0
|
||||
output=$(run_perftest_loopback 0 1 ib_write_bw -d "$dev" --report_gbits 2>/dev/null | grep 65536 | awk '{print int($3)}')
|
||||
|
||||
if [[ -n "$output" ]]; then
|
||||
while read -r bw; do
|
||||
if (( bw < 360 )); then
|
||||
if (( bw < 80 )); then
|
||||
bandwidth_error=1
|
||||
break
|
||||
fi
|
||||
|
|
@ -188,6 +192,57 @@ for i in {0..7}; do
|
|||
echo "node_cluster_check_ib_bandwidth{device=\"$dev\"} $bandwidth_error" >> $TMP_FILE
|
||||
done
|
||||
|
||||
#16 PCIE 降速
|
||||
# PCIe速度与Gen版本对应表
|
||||
declare -A PCIE_SPEED=(
|
||||
["2.5"]="1" # Gen1
|
||||
["5.0"]="2" # Gen2
|
||||
["8.0"]="3" # Gen3
|
||||
["16.0"]="4" # Gen4
|
||||
["32.0"]="5" # Gen5
|
||||
["32"]="5" # 适配整数表示
|
||||
)
|
||||
|
||||
# 识别NVIDIA 3D控制器
|
||||
GPU_DEVICES=$(lspci | grep -i "nvidia" | grep -i "3D controller" | awk '{print $1}')
|
||||
GPU_COUNT=$(echo "$GPU_DEVICES" | wc -l | tr -d ' ')
|
||||
|
||||
# 遍历每个GPU设备
|
||||
INDEX=0
|
||||
while IFS= read -r DEVICE; do
|
||||
[ -z "$DEVICE" ] && continue
|
||||
|
||||
# 获取PCIe信息
|
||||
PCI_INFO=$(lspci -vv -s "$DEVICE")
|
||||
|
||||
# 提取链路能力(LnkCap)
|
||||
LNK_CAP=$(echo "$PCI_INFO" | grep "LnkCap:" | head -n 1)
|
||||
LNK_CAP_SPEED=$(echo "$LNK_CAP" | grep -oP 'Speed \K[\d.]+(?=GT/s)')
|
||||
LNK_CAP_WIDTH=$(echo "$LNK_CAP" | grep -oP 'Width \Kx\d+')
|
||||
CAP_GEN=${PCIE_SPEED[$LNK_CAP_SPEED]:-0}
|
||||
|
||||
# 提取当前状态(仅用于判断降速,不输出详细指标)
|
||||
LNK_STA=$(echo "$PCI_INFO" | grep "LnkSta:" | head -n 1)
|
||||
LNK_STA_SPEED=$(echo "$LNK_STA" | grep -oP 'Speed \K[\d.]+(?=GT/s)')
|
||||
LNK_STA_WIDTH=$(echo "$LNK_STA" | grep -oP 'Width \Kx\d+')
|
||||
STA_GEN=${PCIE_SPEED[$LNK_STA_SPEED]:-0}
|
||||
|
||||
# 判断是否降速
|
||||
DOWNGRADED=0
|
||||
if [ "$CAP_GEN" -gt "$STA_GEN" ] || [ "$LNK_CAP_WIDTH" != "$LNK_STA_WIDTH" ]; then
|
||||
DOWNGRADED=1
|
||||
fi
|
||||
# 只输出链路能力和降速状态指标
|
||||
#echo "# HELP node_cluster_check_gpu_lnkCap GPU支持的最大PCIe链路规格" >> "$TMP_FILE"
|
||||
#echo "# TYPE node_cluster_check_gpu_lnkCap gauge" >> "$TMP_FILE"
|
||||
#echo "node_cluster_check_gpu_lnkCap{device=\"$DEVICE\",index=\"$INDEX\",max_speed_gtps=\"$LNK_CAP_SPEED\",max_gen=\"$CAP_GEN\",max_width=\"$LNK_CAP_WIDTH\"} 1" >> "$TMP_FILE"
|
||||
#echo "# HELP node_cluster_check_gpu_downgraded GPU是否降速(1=是,0=否)" >> "$TMP_FILE"
|
||||
#echo "# TYPE node_cluster_check_gpu_downgraded gauge" >> "$TMP_FILE"
|
||||
echo "node_cluster_check_gpu_downgraded{device=\"$DEVICE\",index=\"$INDEX\"} $DOWNGRADED" >> "$TMP_FILE"
|
||||
INDEX=$((INDEX + 1))
|
||||
done <<< "$GPU_DEVICES"
|
||||
|
||||
|
||||
# 替换指标文件
|
||||
mv $TMP_FILE $METRIC_FILE
|
||||
chmod 777 $METRIC_FILE
|
||||
Loading…
Reference in New Issue